In the San Marcos area, AirOne Rescue is well known for providing exceptional furnace repair, installation, and service. The people we send out to serve you are also top notch, something you'll see in their reviews below. Everyone you deal with at our company has the goal of making sure your experience with us will be so good you'll call us every time you need help. You can feel confident working with AirOne Rescue because we stand behind our work and comply with all local codes. This is why, as you can see by the map and reviews below, we are rated so highly for Heater and AC Repair in San Marcos, TX | AirOne Rescue (31). Call us today at (512) 392-0022!
Service and repair on a Carrier Infinity Greenspeed HVAC heat Pump system. The inverter board is out. Replacing the inverter board
Carrier HVAC heat pump Air Conditioning system maintenance, service and inspection. Grass needs to be trimmed around the system
Commercial
Commercial
IAQ indoor air quality
Drain line for the hvac heat pump air conditioning system was clogged. Cleaning out drain line
some rust on the evaporator coil. Evaporator coil is not leaking at this time, but this amount of rust is not a good sign for the longevity of the system.
Maintenance on hvac air conditioning system
Service on a HVAC Heat Pump Air Conditioning system. The unit was leaking water. The drain system is clogged. Cleaning drain line
Replace bad condenser fan motor
Residential HVAC service on a Trane Heat Pump Air Conditioning system. Adding refrigerant along with leak sealer in an attempt to prevent further refrigerant leaks
Residential HVAC heat pump inspection and Air conditioning check. Mold starting to grow on the system. Zone control systems are notorious for this. Cleaning mold and doing a duct cleaning
Residential Air Conditioning Maintenance on a Heat Pump Carrier System
Dryer vent cleaning
Commercial
Commercial
HVAC Heat Pump Air Conditioning maintenance and service. We found a lot of dust in the HVAC system
Commercial
HVAC Air Conditioning maintenance on a Carrier System. Condenser was dirty and needed to be cleaned and serviced. Though there wasn't a lot of leaves in the bottom of the condenser, it was impacted with fine duct. Cleaning the condenser by washing it with coil cleaning solution.
Residential
Residential Hvac Air conditioning service on a carrier system heat pump
Mold in an air handler and duct system. System needs duct cleaning and evaporator coil and air handler cleaning
Residential HVAC air conditioning heat pump service
Dirty evaporator coils will cause drain line clogs which can cause water to start dripping from your ceiling or trip the float switch and make the thermostat go blank. Cleaning drain line and providing options to clean the evaporator coil
Residential service work. Replacement of UV ultraviolet bulb in air handling unit
Installation,Bronze
Service on a Carrier Air Conditioning system
Maintenace and service on a Carrier Infinity Greenspeed Inverter system. It is important to have surge protection and voltage regulation on these Heat Pump HVAC systems as these boards are very expensive
commercial kitchen repair
Commercial
warranty
Commercial
Old goodman Hvac Gas Furnace system. Very old and poorly installed. Providing Estimates to repair and restore and maintain system with regular service and inspection
The filter on this HVAC Heat Pump system had not been changed regularly. This caused a lot of dust to accumulate on the Evaporator coil. This caused the system to not cool very well, even freeze up at times. We cleaned the coil and it is working much better now
A well maintained Carrier HVAC heat pump system
Dirty ducts are a serious health concern as they harm the quality of the air you breath. Having your ducts cleaned every 3-5 years is what the EPA recommends to keep your Indoor Air Quality ( IAQ ) good and healthy
This UV bulb was well past its lifespan. You can see bacteria starting to grow on the bulb itself. When Ultraviolet Lights get old, they loose their ability to kill bacteria and mold and can actually act as a grow light. This picture also shows the limitations of UV light. You can see the badge at the bottom of the evaporator coil has mold on it because it is not in direct view of the Ultraviolet Lamp. Will provide options for removing the mold